Facsimile · p. 195
— 148 — This plant has proved a great improvement on the old units used, and although its economy would be increased by the installation of a more efficient pump, it has nevertheless widened the margin of profit in a very satisfactory manner.
A further economy would be effected by superheating, for with the existing arrangement of steam pipes there occur considerable condensation losses.
4th Trial of Plant No. 2. Shambat.
Date Duration of ti'ial...
Kind of fuel used Steam pressure at boilers Steam pressure at engine Vacuum Indicated Horse-power :— High-pressure cylinder Low-pressure cylinder ...
Total Weir reading Discharge from pump Discharge from pump Total lift of water ...
Water Horse-power Combined efficiency of engine and pump Total fuel fired Fuel fired per hour Fuel fired per W.H.P. per hour Total feed water...
Steam used per hour by feed pump ...
Steam used per hour by engine Steam used per I.H.P. per hour Temperature of feed water Water evaporated per lb. fuel as fired Equivalent evaporation from and at 212" F.
Cost per W.H.P. hour Cost per 1,000 m" water dehvered